Skip to content

Manager Protocol

bilbycast-edge connects outbound to its bilbycast-manager via a persistent, authenticated WebSocket. The manager pushes commands; the edge pushes stats, health, thumbnails, and operational events back. This page is a capability overview — full message schemas, payload shapes, and protocol extension rules are provided to commercial licensees and integration partners under NDA.

The manager can drive the complete lifecycle of a managed edge without the operator touching the node’s config.json:

  • Read the running config, with node-bound infrastructure secrets stripped so they never leave the device. Flow-level credentials that the operator entered (SRT passphrases, RTSP creds, RTMP keys, bearer/HLS tokens) are preserved so the manager UI can display and round-trip them.
  • Update config — either the whole config or a single flow. Updates are diff-based: unchanged flows are not disturbed, and output-only changes are hot-applied without interrupting the flow’s other outputs.
  • Activate an input — and only this command moves what is on air. A whole-config push, including a config-history restore, pins every passthrough flow’s inputs[].active back to whatever the node already has on air, so replaying a stale copy of the config can never perform a Take as a side effect of an unrelated edit. Two cases take the pushed value instead: assembled (PID-bus) flows, which never read the flag, and a flow with nothing on air yet. The one exception is a push that deletes the on-air input — with no incumbent left to hold, the edge promotes a survivor (preferring the member the pushed config flags active) by moving the pointer only, never splicing an assembled flow’s program.
  • Create / update / delete / start / stop / restart flows, individually.
  • Hot-add and hot-remove outputs on a running flow without dropping live SRT connections or other in-flight outputs.
  • Hot-add and hot-remove inputs on a running flow. A change to a flow’s input roster is applied surgically, so the flow’s outputs keep running across the edit, and editing a standby input’s definition is applied in place (remove + add) — the on-air input is never disturbed. The edge escalates to a full flow restart only when it refuses the surgical path: the edited member is the flow’s active input, a PID-bus slot source, or a leg of a hitless slot.
  • Hot-swap a flow’s assembly plan on a running assembled flow. Unchanged slots keep their bus fan-ins with no packet gap; PMT.version_number bumps mod 32 for changed programs, PAT.version_number only when the set of programs changes, and PSI is re-emitted immediately so receivers see the new PMT before any packet lands on a new out_pid. Transitions across the passthrough ↔ assembled boundary are rejected — those need a full update. See Flow Assembly (PID Bus).
  • Manage tunnels — create (an upsert) and delete. There is no separate start / stop verb: create_tunnel establishes the tunnel the moment it lands and delete_tunnel tears it down. A tunnel’s enabled flag only decides whether the node brings that tunnel up at boot, so clearing it in a pushed config does not stop a running tunnel until the edge restarts.
  • Start and stop flow groups atomically. Multi-essence bundles (e.g., ST 2110-30 audio + ST 2110-31 transparent + ST 2110-40 ANC as one program) are brought up or down as a single logical unit, with automatic rollback on partial failure so a receiver never sees one essence without its companions.
  • Rotate the node’s authentication secret on a live connection. The new secret is written to the edge’s encrypted secrets file atomically; old secrets are invalidated by the manager once the edge has acknowledged the write. No downtime, no WebSocket drop.
  • Run on-demand diagnostics — probe an input or output before committing it (refused while that entity is attached to a running flow, so a test can never steal a live port), measure a bonded leg’s reachable capacity against a peer’s probe responder, check a cellular or Starlink uplink, and reset a flow’s statistics counters.

The edge emits four kinds of outbound messages:

Message Cadence Purpose
stats every 1 s Per-flow input/output bitrates, packet counts, FEC stats, TR 101 290, IAT / PDV
health every 15 s Node-level health, software version, capability list
thumbnail every 5 s per flow (configurable 1–60 s) 320×180 JPEG preview (when enabled)
event on state change Operational events with severity, category, optional flow_id and details — see Events & Alarms

Events are deduplicated — they fire on state transitions, not periodically — and queued when the manager is disconnected so a reconnect delivers the backlog.

Two classes of secret are treated differently:

  • Infrastructure secrets (node↔manager auth, tunnel keys and bind secrets, server TLS, OAuth client credentials) are device-bound. They are never returned to the manager on config reads. When the manager pushes a config update, the edge re-injects its local infrastructure secrets before applying.
  • Flow-level user credentials (the passphrases and tokens an operator types into the manager UI) are preserved through config reads so the UI can show and round-trip them.

This split means the manager can be compromised without exposing any node-bound credential, while the operator UX of “I typed this passphrase into the manager; I expect to see it there” is preserved.

The protocol is designed to evolve without breaking running deployments. Edges advertise a protocol_version and software_version at connect time; newer edges and older managers (or vice versa) coexist cleanly. The current version is 4, which added the native binary media-library upload frame — an edge below it is refused that one upload with a compatibility warning event rather than being left to drop the frame silently (see Media Library). Unknown message types on either side are logged and ignored rather than tearing down the connection. The same resilience pattern applies to the edge ↔ relay tunnel protocol.