Remote Upgrade
The manager can upgrade every connected edge node and gateway sidecar over the existing WebSocket link — no SSH, no shell scripts on each box, no fleet-wide outage during a rolling release. Operators pick a version in the manager UI; the target node downloads + verifies the new build, atomically swaps a symlink, and respawns under systemd.
This page is the operator’s runbook. The cryptographic trust model and the edge-side staging machinery live in the edge upgrade reference and the security model — those documents matter if you’re auditing the supply chain. Most operators only need this page.
What the manager can upgrade
Section titled “What the manager can upgrade”- bilbycast-edge nodes
- Gateway sidecars built on
bilbycast-gateway-sdk— today that means bilbycast-appear-x-api-gateway, and any future first- or third-party sidecar that opts into the same machinery
Manager and relay binaries are upgraded manually today. The same Sigstore-signed releases ship for them, but there’s no manager-driven rollout — see Install the manager and Install the relay for the manual flow (and the optional Sigstore-verification step on each).
Prerequisites — first install
Section titled “Prerequisites — first install”Manager-driven upgrade only works once the node is already installed and registered. The first install always uses the curl-pipe-bash one-liner:
- Edge: see Install an edge node → Install edge as a Linux service
- Sidecar: see Appear X gateway setup
Both installers lay out /opt/bilbycast/<service>/{current,versions/<v>/,state.json,config…} with current as a symlink the upgrade machinery atomically swaps. After the first install, every subsequent upgrade is the manager-driven flow on this page.
Per-node upgrade (UI)
Section titled “Per-node upgrade (UI)”- Sign in to the manager as Operator or higher (group-scoped — Operator on the node’s owner group).
- Navigate to Managed Nodes (
/admin/nodes). - Find the row for the node you want to upgrade. The Actions column shows an Upgrade… button only when the node has advertised the
"upgrade"capability on its most recent health beat. Older nodes that predate the upgrade module hide the control automatically. - Click Upgrade…. The modal opens and queries the available released versions for that node’s binary (cached server-side for 5 min).
- Pick a
(version, channel):- stable is the only channel published today.
- The dropdown lists the most recent ~10 releases. Pick the one you want.
- Click Stage upgrade.
- The modal closes and the node row’s Version column starts showing a small badge:
upgrading— the edge is staging (downloading + verifying + extracting + symlink swap)updated— completed; the node is now running the new versionupgrade failed— staging rejected the release. Hover for the structurederror_code(e.g.upgrade_signature_invalid,upgrade_checksum_mismatch,upgrade_disk_full).
Steady-state, the whole flow takes ~30 seconds for a small binary on a fast link. The node briefly disconnects from the WebSocket while systemd respawns it; the manager treats that as an in-flight upgrade and waits for the new binary to re-authenticate with the new software_version.
Group bulk rollout (UI)
Section titled “Group bulk rollout (UI)”For larger fleets the per-node flow is tedious. Group Admin users can roll out a release across every node in a group with one action:
- Navigate to Groups (
/admin/groups) and pick the target group. - Click Upgrade group.
- Pick
(version, channel)and a strategy:- Staged (recommended) — the manager fans out the upgrade in three waves: 10% canary → 50% wave → 100% wave, with a 5-minute settle window between waves. If any node in a wave fails staging, the orchestrator pauses and the remaining waves do not run. You retry after fixing the underlying issue.
- Immediate — every node in parallel. Use this for small clusters or test environments.
- Click Stage rollout. The modal returns immediately with the wave plan; the actual rollout proceeds in the background. Watch the Events page (filter category:
upgrade) for live progress.
Rollback — automatic
Section titled “Rollback — automatic”Every staged upgrade is gated by a boot watchdog on the target. If the new binary fails to come up healthy within boot_health_window_secs (default 120 seconds) after max_boot_attempts (default 3) systemd respawns, the watchdog reverts the symlink to the previous version and emits an upgrade_rolled_back Critical event. No operator action required.
Rollback is your safety net — a botched build can’t take a node offline indefinitely. The previous version is kept in versions/<old>/ and the symlink revert is atomic.
If you need to roll back a successful upgrade after the boot health window has passed (the new version started healthy but caused a regression in production), schedule another upgrade from the manager UI to the previous version. The same staging path runs in reverse.
Trust model — what the manager can and can’t do
Section titled “Trust model — what the manager can and can’t do”The manager has authority over scheduling an upgrade (which node, when, which version), but never over what code runs. The bytes are gated by the edge’s compiled-in Sigstore allowlist:
- The manager sends
upgrade_binary { version, channel }over the existing authenticated WebSocket. - The target node fetches
manifest.json+manifest.sig.bundlefrom GitHub Releases. - The node verifies the manifest signature against its compiled-in
ALLOWED_SIGNERSallowlist (Sigstore Fulcio cert binding the workflow run identity, plus a Rekor transparency log lookup). - Only then does it use the SHA-256 in the verified manifest to download the tarball, recheck the hash, extract, and atomically swap.
- systemd respawns into the new binary via the
currentsymlink.
A fully compromised manager can only schedule a real, Sigstore-signed Bilbycast release. It cannot install arbitrary code.
The same trust roots are used by the curl-pipe-bash installer at first install, and by every manual cosign verify-blob an operator chooses to run.
Audit trail
Section titled “Audit trail”Every upgrade attempt is recorded in the audit log (/admin/audit):
| Action | Trigger | Details |
|---|---|---|
node.upgrade.request | per-node upgrade | {version, channel} |
group.upgrade.schedule | group rollout | {version, channel, strategy, node_count} |
group.upgrade.paused | rollout pause-on-failure | {version, failure_count} |
group.upgrade.complete | rollout finished | {version, completed_count} |
Plus the lifecycle events (upgrade_started, upgrade_downloaded, upgrade_staged, upgrade_completed, upgrade_rolled_back, upgrade_*_failed) ride the normal events stream under category: upgrade for dashboard / SIEM consumption.
Troubleshooting
Section titled “Troubleshooting”| Badge / error_code | Meaning | Fix |
|---|---|---|
| Upgrade button missing | Node’s last health beat didn’t advertise "upgrade" capability | Update the node manually once to a version that has the upgrade module. From then on the button appears. |
upgrade_disabled | Operator left [upgrade] enabled = false (or omitted the section) in the node’s local config | SSH to the node, set enabled = true in [upgrade], restart the service. |
upgrade_channel_not_allowed | Node’s [upgrade] allowed_channels doesn’t include the requested channel | Add the channel locally and restart. |
upgrade_version_too_old | Node’s [upgrade] min_version is higher than the requested version | Pick a newer version. |
upgrade_signature_invalid / upgrade_identity_not_allowed | The manifest’s Sigstore signature didn’t pass — either tampering or a release workflow path that doesn’t match the node’s compiled-in allowlist | If you renamed the release workflow recently, you must publish a new release from the OLD workflow first that carries the new allowlist. |
upgrade_checksum_mismatch | The downloaded tarball’s SHA-256 doesn’t match what the verified manifest claims | Network corruption or release-asset tampering. Retry; if it persists, file a security issue. |
upgrade_disk_full | Less than ~3× the tarball size free on the install root | Free up disk on the node. |
upgrade_rolled_back | The new version failed to come up healthy; watchdog reverted | Inspect journalctl -u bilbycast-edge -e on the node for the actual failure. The node is running the previous version again — safe to investigate. |
For deeper diagnostics, the edge ships a per-event details.error_code on every category: upgrade event — filter the events page by that category to see the full state machine.
See also
Section titled “See also”- Install an edge node — first-time install via curl-pipe-bash
- Install the manager — manager itself (manual upgrade)
- Install the relay — relay (manual upgrade)
- Appear X gateway setup — first-time sidecar install
- Multi-tenant Groups — RBAC and group-scoped operator permissions